4 stages Charge algorithm by steps
1. Qualification:
Ensure the battery in good condition prior to charge. Charge will not be started if battery is less than 2.0V.
2. Bulk charge:
The normal charge is commenced to deliver the constant current for charging up the battery until 80% full.
3. Absorption charge:
The charge program has switched over to Constant voltage; the charge current has to be reduced according to the raised of battery level, until the battery is full.
4. Maintenance:
The battery can be permanently maintained at a proper work level and to be kept ready to go.
 
  4 Steps Intelligent battery charging program
(Qualification, Bulk charge, Absorption, Real Float maintenance mode)
     
 
9 Steps Intelligent battery charging program
(Qualification, Battery Recover mode, Soft Start, Pulse mode, Recondition, Bulk charge, Absorption, Checking, Real Float maintenance mode)
 
  9 stages Charge algorithm by steps
1. Qualification:
Ensure the battery in good condition prior to charge. Charge will not be started if battery is less than 2.0V.
2. Battery Rescue:
Battery Rescue starts, in case the battery voltage has unusually raised to the highest voltage at the beginning of charge.
3. Soft Start:
Soft Start follows when battery is rescued successfully, it delivers limited current to re-active the element of battery for better charging condition.
4. Pulse Mode:
Pulse mode starts in case the battery has detected at very low level when the charge commences.
5. Recondition:
Recondition follows when the Pulse mode is completed, it aims to re-active the element of battery for battery charging condition.
6. Bulk charge:
The normal charge is commenced to deliver the constant current for charging up the battery until 80% full.
7. Absorption charge:
The charge program has switched over to Constant voltage; the charge current has to be reduced according to the raised of battery level, until the battery is full.
8. Checking:
It checks the battery voltage after charged, to make sure the voltage can be retained otherwise the battery is classified a dead battery.
9. Maintenance:
The battery can be permanently maintained at a proper work level and to be kept ready to go.
 
 
Two ways Battery Recover mode
 
  Battery Rescue by Steps
1. Charge is commenced:
Charger connects to mains Power and battery
2. Checking:
Charger delivers high voltage to check the battery status
3. Battery is at normal level:
If battery is detected within the normal level, then charge will commence as usual
4. Charge Started:
The normal charging program is started.
5. The Battery Rescue starts, if battery has raised excess the normal
    level in few seconds:
Charger delivers a higher voltage but lower current for rescue attempt until the battery volt has reduce to specify level, then the normal charge will come up. In case the battery voltage is unable to reduce after specified period, then charge terminates, as it is not recommended to recharge a dead battery.
6. Battery Rescue successes:
In case the battery volt is able to reduce below specified level, then it will go back to first stage.
7. Battery Rescue Fails:
In case the battery is unable to recover after specified time period. The charge will then stop, and the indicator of “Bad Battery” is lighted up for showing bad battery status
8. Bad Battery :
The charge will then terminate. No charge current will be delivered.